Skip to main content
BiomeFx
Updated over 4 months ago

Test Details

Lab Company: Microbiome Labs
​Sample Type: Stool
​Collection Location: At Home

BiomeFx measures the balance of pathogens and beneficial microbes that make up your microbiome.


Key Details

  • 🚫 No special preparation is needed.

  • 🌑️ Keep your sample at room temperature until shipping.

  • πŸ“¦ Keep the test kit box to ship your sample back to the lab.

  • 🚚 Ship your sample via USPS within 7 days of collection.

  • πŸ“„ You must complete the online test registration and consent forms. Failure to complete these forms may result in delayed results or a recollection.


Preparation & Timing

  • No special preparation is needed.


Collection Instructions

  1. Complete the online test registration and consent forms.

    1. Both forms will be emailed to you from Microbiome. Please complete these forms so that your sample can be processed at the laboratory. Failure to complete the registration and consent forms may result in delayed results or a recollection.

  2. Open the Feces Catcher following the directions on the package.

  3. Adhere the Feces Catcher to the toilet seat.

    1. The Feces Catcher will go around/over the toilet seat.

    2. Ensure the Feces Catcher does not touch the water.

    3. Tip: It may be helpful to put plastic wrap loosely over the toilet before placing the Feces Catcher on the toilet seat. This will help prevent the Catcher or your stool from getting in the water.

  4. Collect your stool in the Feces Catcher.

  5. Remove the purple top of the collection tube.

    1. DO NOT touch or discard the liquid in the tube.

    2. DO NOT remove the yellow tube top.

  6. If your kit was ordered before August 2, 2024,

    1. Use the spatula to remove a small amount of stool.

    2. Transfer the stool to the top portion of the yellow tube top.

      1. DO NOT push the stool into the tube.

    3. Repeat steps 6a and 6b until the stool fills the yellow tube top.

    4. Use the spatula to scrape horizontally across the yellow tube top. This will level the stool sample and remove any excess.

    5. Go to step 8.

  7. If your kit was ordered on or after August 2, 2024,

    1. Use the provided spoon to collect one spoonful of stool.

      1. DO NOT collect more than one spoonful.

    2. Transfer the stool to the top portion of the yellow tube top.

    3. Go to step 8.

  8. Screw the purple tube top onto the yellow tube top tightly.

  9. Clean off any stool that may have gotten on the outside of the tube.

  10. Shake the sealed tube for a minimum of 30 seconds.

  11. If large particles remain, continue shaking until they have disappeared.

  12. Place the spatula back in its packaging and discard.

  13. Loosen the Feces Catcher on both ends.

  14. Press the ends of the Feces Catcher together.

  15. Drop the Feces Catcher in the toilet.

  16. Once the paper is soft, flush the Feces Catcher and the remaining stool.

  17. Prepare your sample for shipping.

    1. Place the collection tube into the plastic zip-lock bag.

    2. Place the plastic zip-lock bag into the biohazard bag.

  18. Take a picture of your 14-digit sample ID (on the sample collection tube). You may need this number if there is an issue with your sample.


Requisition & Payment

  • Your kit has been prepaid. You DO NOT need to pay anything extra.

You must register your test online and complete the emailed consent form.

Failure to complete these forms may result in delayed results or a recollection.

  • Take a picture of your 14-digit sample ID (on the sample collection tube). You may need this number if there is an issue with your sample.


Shipping

  • Ship your sample within 7 days of collection.

  • If your kit was ordered before August 2, 2024,

    • Place the collection tube into the plastic zip-lock bag.

    • Seal the bag.

    • Place the plastic zip-lock bag into the biohazard bag.

    • Seal the bag.

    • Place the biohazard bag into the provided return envelope.

    • Seal the return envelope.

    • Place the provided, prepaid return label onto the envelope.

  • If your kit was ordered on or after August 2, 2024,

    • Place the collection tube into the plastic zip-lock bag.

    • Seal the bag.

    • Place the plastic zip-lock bag into the biohazard bag.

    • Seal the bag.

    • Place the biohazard bag into the kit box.

    • Seal the kit box.

  • Make a note of the tracking number so that you can track your sample back to the lab.

  • Take your sample to the nearest USPS office to ship.

    • DO NOT place your sample in a USPS drop box.


Results

  • Results should be released to your provider 2 to 3 weeks after the sample is received at the lab. Rupa Health cannot guarantee processing time.


More Resources


Questions?

Reach out to Rupa Health via the chat in your patient portal.

Did this answer your question?